>200kVA Range
LQLVF 250kVA/2*83.3A Power Noise Filter: High-Voltage EMI Suppression with Ultra-Low Partial Discharge
Premium HV Noise Attenuation
Engineered for critical EMI suppression in 3kV industrial power systems:
40KHz-100KHz range: >40dB attenuation
100KHz-1MHz range: >60dB attenuation
Background partial discharge: <3pC (ultra-low level)
Filter reactor quality factor: >70
Dual-frequency compatibility (50-60Hz)
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 250kVA |
Rated Voltage | 3kV Input/Output |
Current Rating | 2 × 83.3A |
Frequency Range | 50-60Hz |
Circuit Configuration | Dual Independent Circuits |
Insulation Level | 5kV/1min withstand |
Continuous Operation | 60 min at 100% rated load |
Installation | Sub-stage switchgear cabinet |
Ultra-Low Partial Discharge Design
Advanced engineering for sensitive electrical environments:
Background PD level <3pC at rated voltage
Triple-shielded reactor construction
Corona-suppression encapsulation technology
PD-monitoring compatible terminal points
Validated per IEC 60270 measurement standards
High-Voltage Insulation System
Robust protection for 3kV applications:
5kV/1min dielectric strength (exceeds IEC 60664 requirements)
Class F insulation system (155°C rating)
Enhanced creepage distance: ≥25mm/kV
Corona-free design up to 3.6kV operational voltage
Partial discharge inception voltage >4.0kV
Switchgear Integration Design
Optimized for HV switchgear cabinet installations:
Compact dimensions for retrofitting existing compartments
Front-access terminals with safety shrouds
Vibration-resistant mounting system
Thermal management for enclosed spaces
HV cable entry points with silicone rubber grommets
Industrial Applications
Ideal for 3kV systems in:
Industrial HV switchgear installations
Power generation substations
Utility transmission systems
Renewable energy converter stations
High-voltage test laboratories
Marine power distribution systems
Dual-Circuit Reliability
Enhanced system performance and redundancy:
Independent circuits for critical applications
Asymmetric load balancing capability (±15%)
Individual circuit monitoring points
Fault isolation protection per circuit
Parallel operation capability
Installation & Maintenance Protocol
Ensure optimal performance in switchgear applications:
Verify cabinet dimensions ≥600×500×800mm (W×D×H)
Use silicone-insulated HV cable (8kV rating minimum)
Maintain minimum 150mm clearance to grounded surfaces
Torque HV terminals to 80 N·m ±3%
Perform semi-annual partial discharge scans
Test insulation resistance annually (≥500MΩ at 5kV DC)
Monitor attenuation performance every 24 months
Safety & Protection Systems
Engineered for reliable HV operation:
Arc-resistant containment barriers
Over-temperature protection with lockout
Surge protection (20kV/20μs withstand)
Ground fault monitoring with isolated relays
Automatic discharge circuits
IP55-rated enclosure for harsh environments
Compliance & Standards
Meets international HV requirements:
IEC 62271-200 for AC metal-enclosed switchgear
IEEE C57.12.00 liquid-immersed equipment
EN 50522 earthing of power installations
IEC 60076-6 power reactor standards
IEC 61000-3-12 harmonic emissions
ANSI/IEEE C57.12.90 test code
For HV switchgear integration guides or custom solutions, contact our specialized engineering team. Performance validated per IEC 60270 partial discharge standards.