High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>200kVA Range

LQLVF 250kVA/2*416.6A Power Noise Filter | ONAN Cooled High-Current EMI Solution

250kVA dual-circuit noise filter with 416.6A rating, ONAN cooling, and <2pC partial discharge. 60dB attenuation for pre-stage cabinet installation in 0.6kV systems.


  • US$ 4,509.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQLVF 250kVA/2*416.6A Power Noise Filter: High-Current EMI Suppression with ONAN Cooling

Premium Broadband Noise Attenuation

Engineered for critical EMI suppression in industrial 0.6kV systems:

  • 40KHz-100KHz range: >40dB attenuation

  • 100KHz-2MHz range: >60dB attenuation (extended high-frequency coverage)

  • Ultra-low background partial discharge: <2pC

  • Dual-circuit design for balanced load distribution

Technical Specifications

ParameterSpecification
Rated Capacity250kVA
Rated VoltageInput/Output: 0.6kV
Current Rating2 × 416.6A (833.2A total)
Frequency50Hz
Phase ConfigurationSingle Phase
Cooling SystemONAN (Oil Natural Air Natural)
Insulation Level3kV/1min (no abnormal discharge)
Continuous Operation60 min at 100% rated load
InstallationPre-stage Cabinet

Advanced ONAN Cooling Technology

Optimized thermal management for high-current applications:

  • Mineral oil insulation with natural convection cooling

  • Temperature rise limit: 65°C at full load

  • Designed for ambient temperatures up to 45°C

  • Expansion tank with nitrogen cushion

  • Optimized radiator fins for efficient heat dissipation

High-Current Dual-Circuit Design

Robust engineering for demanding industrial applications:

  • 833.2A total current capacity (2×416.6A)

  • Low-impedance copper busbar design (≤0.08mΩ)

  • Copper windings with 200% short-circuit withstand

  • Dynamic load response time <5ms

  • Parallel operation capability for higher current needs

Ultra-Low Partial Discharge Design

Premium EMI suppression for sensitive equipment:

  • Background PD level <2pC at rated voltage

  • Triple-shielded reactor construction

  • Corona-resistant encapsulation technology

  • PD-monitoring test points integrated

  • Validated per IEC 60270 measurement standards

Pre-Stage Cabinet Integration

Optimized for installation in upstream power distribution:

  • Compact form factor for pre-stage cabinet retrofitting

  • Front-access terminals for maintenance access

  • Vibration-resistant mounting brackets

  • Thermal alignment with cabinet airflow patterns

  • Standardized cable entry points (50mm knockouts)

Industrial Applications

Ideal for 0.6kV systems in:

  • Industrial power distribution pre-stages

  • Large motor control centers

  • Foundry and smelting operations

  • High-power test facilities

  • Process manufacturing power systems

  • Heavy industrial equipment power lines

Installation & Maintenance Protocol

Ensure optimal performance in pre-stage cabinets:

  1. Verify cabinet clearance ≥400mm for natural convection

  2. Use compression lugs rated for 500A connections

  3. Check oil dielectric strength ≥40kV before commissioning

  4. Torque power terminals to 70 N·m ±5%

  5. Perform semi-annual insulation resistance tests

  6. Monitor oil temperature quarterly during peak loads

  7. Conduct partial discharge scans annually

Safety & Protection Systems

Engineered for reliable high-current operation:

  • Pressure relief device with alarm contacts

  • Buchholz relay for gas detection

  • Dual RTD temperature sensors (oil and winding)

  • Surge protection (15kV/20μs withstand)

  • Automatic discharge circuit for capacitors

  • IP54-rated enclosure for industrial environments

Compliance & Standards

Meets international requirements including:

  • IEC 60076 power reactor standards

  • IEEE C57.12.00 liquid-immersed equipment

  • EN 50588-1 medium-power transformers

  • IEC 61000-3-12 harmonic emissions

  • ANSI/IEEE C57.91 thermal loading guide

  • UL 506 standard for power transformers

For pre-stage cabinet integration guides or custom high-current solutions, contact our engineering team. Performance validated per IEEE 1137-2018 test standards.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message