High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Isolation Transformer

LQHIT 55KVA Double Shield Isolation Transformer: 380V to 380V/220V with >10dB Noise Damping

55KVA oil-immersed isolation transformer with dual electrostatic shielding and >10dB noise damping. 380V input with dual 380V/220V outputs. ONAN cooling for continuous operation in demanding environments.


  • US$ 2,583.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHIT 55KVA Double Shield Isolation Transformer: 380V Input to Dual 380V/220V Outputs

Premium Noise Suppression for Critical Power Systems

Engineered for industrial environments with severe electromagnetic interference, this transformer features dual electrostatic shields that deliver >10dB noise attenuation across the 15kHz-1MHz spectrum. The specialized copper-mesh barriers between HV/LV windings and coil assemblies effectively minimize partial discharge interference in sensitive measurement systems, ensuring signal integrity for precision instruments.

Technical Specifications

ParameterSpecification
Rated Capacity55 kVA
Input Voltage380V AC (50Hz)
Output Voltages380V AC + 220V AC (Independent Circuits)
Input Current145A
Output Currents131.5A (380V) / 22.7A (220V)
Noise Damping>10dB (15kHz-1MHz range)
Cooling SystemONAN (Oil Natural Air Natural)
Weight650kg
Dimensions (W×D×H)800mm × 600mm × 100mm
Footprint Area0.48m²

Dual Shield Engineering Advantages

1. Primary Electrostatic Shield (HV-LV)

Copper-foil barrier eliminates capacitive coupling, reducing common-mode noise by 95% compared to single-shield designs. Essential for high-frequency measurement accuracy.

2. Secondary Shield (LV-Coil)

Prevents core-induced electromagnetic interference, maintaining signal integrity for instruments operating below 0.2mV resolution thresholds.

Optimized ONAN Cooling

Mineral oil thermal management enables 24/7 continuous operation at full load with maximum 55°C temperature rise, exceeding IEC 60076-11 requirements.

Performance Highlights

MetricIndustry StandardLQHIT 55KVA
Noise Suppression25-35dB>45dB
Partial Discharge Reduction40-50%>80%
Voltage Stability±5%±2.8%
Continuous Operation85% load capacity100% load capacity

Industrial Applications

  • High-Voltage Test Facilities: Isolate PD measurement circuits from grid harmonics

  • Industrial Automation: Clean power for robotic assembly lines and CNC systems

  • Renewable Energy Plants: Stabilize output in solar/wind converter stations

  • Medical Diagnostic Centers: EMI-free supply for MRI and CT scanners

  • Research Laboratories: Precision power for sensitive measurement equipment

Installation & Safety Features

  • Low-Profile Design: 100mm height enables installation in space-constrained areas

  • Heavy-Duty Construction: 650kg robust build with reinforced tank walls

  • Enhanced Safety: Pressure-relief diaphragm and over-temperature cutoffs (IEC 61558-2-4 compliant)

  • Environmental Protection: IP55-rated terminals for harsh industrial environments

  • Vibration Resistance: Shock-absorbing mounts rated for 7G operational vibration

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message