Tank Type
HFRS-T 45kV/1350kVA Variable Frequency Resonant Reactor
Engineered for precision high-voltage testing, the HFRS-T 45kV/1350kVA reactor delivers < 1% measurement error and <10pC partial discharge in a rugged metal tank design optimized for field operations.
Core Technical Specifications
Rated Voltage: 45kV (±1% stability)
Rated Capacity: 1350kVA
Current Rating: 30A continuous
Inductance: 5H ±1% @ 20-300Hz
Insulation: 110% rated voltage for 60s
Quality Factor (Q): ≥60-120
Unmatched Performance Metrics
Partial Discharge Control
Maintains < 10pC PD level at 100% rated voltage (per indoor acceptance test protocols with specialized PD measurement methods).
Thermal Management
Winding temperature rise: < 80K
Transformer oil rise: < 55K
Epoxy tube surface rise: ≤40K
Duty Cycle: 1 hour ON / 1 hour OFF (max 3 cycles/day at full 45kV/30A rating)
Robust Mechanical Design
Iron Core with Segmented Air Gap – Precise magnetic flux control
Copper Lead-Wire Windings – Low-loss performance
Oil-Immersed Iron Tank – Superior heat dissipation vs epoxy designs
Integrated Features:
Breather capsule for oil expansion
Heavy-duty lifting hooks
Shock-resistant transport design
Key Advantages Over Epoxy Tube Reactors
Feature | HFRS-T Metal Tank | Epoxy Tube Design |
---|---|---|
Heat Dissipation | 40% more efficient | Limited by material |
Partial Discharge | <10pc guaranteed=""> | Typically 15-20pC |
Field Durability | Impact-resistant shell | Vulnerable to cracks |
Typical Applications
On-site testing of 35-45kV power cables
Factory acceptance tests for distribution transformers
Commissioning of wind turbine step-up transformers
Mobile test labs for utility field services
Compliance & Traceability
Each unit includes a permanent nameplate with:
Rated voltage/inductance/frequency
Serial number for traceability
Weight specifications