Transformer failures cost industries millions annually, often traceable to deteriorating insulating oil. Recognizing these warning signs early with a dielectric loss tester can mean the difference between scheduled maintenance and catastrophic failure.

1. Increased Dissolved Gas Levels

Key gases indicating oil breakdown:

  • Hydrogen (H₂) above 100 ppm suggests thermal faults

  • Acetylene (C₂H₂) indicates arcing at just 1 ppm

  • Ethane (C₂H₆) signals oil overheating

Dielectric loss testing confirms whether gas generation correlates with oil degradation.

2. Rising Operating Temperatures

Temperature patterns that demand testing:

  • 10°C above normal operating temperature

  • Hotspot temperatures exceeding 65°C

  • Erratic temperature fluctuations

Dielectric loss increases exponentially with temperature - a 10°C rise can double tan δ values.

3. Visual Oil Contamination

Visible changes requiring immediate testing:

AppearancePossible ContaminationTypical tan δ Impact
Cloudy/MilkyWater (>30 ppm)Increase 300-500%
DarkeningOxidation productsIncrease 200-400%
ParticulatesSolid contaminantsIncrease 150-300%

4. Abnormal Dissipation Factor History

When historical data shows:

  • tan δ > 0.02 at 90°C (new oil typically <0.005)

  • Yearly increase >0.005

  • Values exceeding manufacturer specifications

5. Scheduled Maintenance Milestones

Mandatory testing intervals:

  • Annual testing for critical power transformers

  • Pre-commissioning of all new/repaired units

  • After oil processing (filtration, degassing)

  • Following overloads or through-faults

Proactive Testing Protocol

Implement this diagnostic approach:

  1. Baseline test with new oil

  2. Quarterly screening tests

  3. Full diagnostic tests at annual intervals

  4. Emergency tests after abnormal events

Conclusion

Recognizing these 5 critical signs and implementing regular dielectric loss testing protects your valuable assets. Modern testers provide the data needed to make informed oil maintenance decisions - whether to continue service, reclaim, or replace. Don't wait for failure - test when these symptoms first appear.

Related News
Read More >>
The Importance of Excitation Current Measurement in Transformer TTR Testing The Importance of Excitation Current Measurement in Transformer TTR Testing
2026-01-17
This article delves into the critical role of measuring excitation···
Key Specifications to Evaluate When Purchasing a Transformer Turns Ratio Meter Key Specifications to Evaluate When Purchasing a Transformer Turns Ratio Meter
2026-01-17
This article provides a detailed checklist of critical technical a···
Case Study: Detecting and Diagnosing Shorted Turns with a Transformer Turns Ratio Meter Case Study: Detecting and Diagnosing Shorted Turns with a Transformer Turns Ratio Meter
2026-01-16
This detailed case study presents a real-world scenario where TTR ···
How to Use TTR Test Results for Transformer Life Assessment and Failure Prediction How to Use TTR Test Results for Transformer Life Assessment and Failure Prediction
2026-01-16
This article explores how historical Transformer Turns Ratio (TTR)···

Leave Your Message