High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kVA ~ 200kVA Range

LQLVF-100kVA/2*152A Low Voltage Filter | 80-90dB EMI Suppression

100kVA low voltage filter with 152A rating, <2pC partial discharge, and 90dB attenuation. 180min continuous operation at 0.38kV for industrial systems.


  • US$ 2,712.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQLVF-100kVA/2*152A Low Voltage Filter: Premium EMI Suppression for Sensitive Equipment

Industry-Leading Attenuation Performance

Delivers exceptional electromagnetic interference suppression for critical low-voltage systems:

  • 40KHz-100KHz range: >80dB attenuation

  • 100KHz-1MHz range: >90dB attenuation

  • Filter reactor quality factor: >70

  • Partial discharge background: <2pC (per IEC 60270)

Technical Specifications

ParameterSpecification
Rated Capacity100kVA
Voltage Rating0.38kV Input/Output
Current Rating2 × 152A
Frequency Range30-300Hz
Circuit Configuration2 independent lines
Insulation Level3kV/1min (no abnormal phenomena)
Continuous Operation180 min at 100% rated load

Ultra-Low Partial Discharge Design

Advanced engineering for sensitive electronic environments:

  • Background PD level <2pC at rated voltage

  • Triple-shielded reactor construction

  • Corona-suppression encapsulation technology

  • PD-monitoring compatible terminal points

Critical Applications

Ideal for noise-sensitive 0.38kV systems:

  • Laboratory measurement equipment

  • Medical diagnostic imaging systems

  • Semiconductor manufacturing tools

  • Precision instrumentation power supplies

  • Research facility power conditioning

Extended Operational Capability

Engineered for demanding operational profiles:

  • 180-minute continuous operation at full load

  • Thermal management system with ±1°C stability

  • Automatic load-cycling for extended duty applications

  • Wide frequency compatibility (30-300Hz)

Installation & Maintenance Protocol

Ensure optimal performance with these guidelines:

  1. Maintain ambient humidity ≤85% non-condensing

  2. Verify parallel line synchronization within 5° phase angle

  3. Perform quarterly partial discharge scans

  4. Annual dielectric absorption ratio (DAR) testing

  5. Monitor filter reactor Q-factor biannually

Compliance & Standards

Meets rigorous international requirements:

  • IEC 61000-3-12 for harmonic current emissions

  • IEEE 519-2022 for harmonic control

  • EN 55011 Class A industrial equipment

  • ANSI/NETA MTS-2019 maintenance standards

  • IEC 60076-6 for reactor safety

For technical support or custom frequency response configurations, contact our engineering team. Performance validated per IEEE 1137-2018 test standards.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message